1.Before the installation of oil-gas boilers, relevant units should determine safe and reliable gas supply methods in accordance with national standards or industrial standards such as GB50028 "Urban Gas Design Code". The pressure vessels, pressure pipes and gas cylinders used in the gas supply system should meet the requirements of relevant safety technical specifications and standards for special equipment.
2.The configuration of the burner must meet the technical requirements of the burner configuration specified in the technical data of the boiler factory. 3. Burners shall meet the requirements of safety technical specifications and standards such as Boiler Safety Technical Supervision Regulations, and oil and gas burners shall pass type tests.
3.The boiler user shall not modify and unlist the operation control program of the burner without permission.
4.The boiler user shall conduct daily inspection of the burner, boiler safety accessories and safety interlocking devices in accordance with the requirements of relevant safety technical specifications for boilers, and make inspection records.
5.When the burner needs to be repaired, the boiler user shall ask the manufacturer of the burner or its authorized unit to do so. 7. After the completion of the installation of new boilers, the system commissioning shall be completed jointly by the boiler user and the boiler erection unit or the boiler manufacturing enterprise. During the commissioning, boiler operators with corresponding qualifications shall carry out the boiler operation.
6.The technical personnel of the boiler manufacturing unit or its authorized unit shall provide on-site guidance when the burner is to be debuged6. The technical personnel of the boiler manufacturing unit or its authorized unit shall provide on-site guidance when the burner is to be debuged7.
7.During the commissioning of the boiler system and burner, the safety management organization of the boiler user unit shall ensure that irrelevant personnel shall not gather near the boiler.
8.The transformation and replacement of the burner shall follow the relevant construction notification procedures in accordance with the provisions of the boiler repair. The burner manufacturer or its authorized unit shall be responsible for the transformation, replacement and commissioning of the boiler burner, and the boiler user shall cooperate with the work. After the transformation and replacement of the burner, the user shall conduct self-inspection of the safety accessories such as the boiler safety valve and safety interlock protection device, and form self-inspection records.
9.Any transformation, repair and replacement of the burner shall not reduce the safety performance and energy efficiency index of the boiler and shall meet the environmental protection requirements.
10.Please read the attached technical data carefully before commissioning, ignition and use of boilers and burners, and carry out the work in strict accordance with the operating procedures.
11.When the burner is working, abnormal movement, abnormal sound or other abnormal conditions, it should stop running in time, find the reason, and continue to use after troubleshooting.
EBICO will attend Thailand's Premier Power Generation & Electric Exhibition...
How a bowl of Baixiang good noodles is born? About 1.8 million years ago, humans learned to cook food with purposeful control of fire. The use of fire has made unprecedented progress in human health and life, and Darwin also called cooking the most important invention of mankind after language....